- Description
Specifications
In the normal display state of SV/PV, press the "Set" button to make the SV display in a flicker state, and then find the desired temperature number by "<" key, and then
Use ∨ "Sunday afternoon" change the Set temperature, and then press the "Set" key, the instrument back to SV/PV according to normal state.
2. In the normal display state, hold the "Set" key for 3 seconds, display the parameter setting status in the PV display, and display its corresponding value in the SV display
In turn, press "Set" key to display the table parameter symbol: (all parameters are fully Set when they leave the factory, please do not tamper with them.)
3. Note: the machine has the function of displaying the reply. When the operator has set the parameters of the operation and forgot to return to the main display mode, the instrument will be free after 30 seconds
The action returns the main display mode, and the changed parameters are not saved
- In view of the working principle and characteristics of the machine, it is recommended that the machine should work for no more than 3 hours, such as work, in order to make the machine more durable
For more than 3 hours, please stop for about an hour before continuing to work.
-Please pay attention to the situation of the crucible at any time, and replace it at any time to avoid any damage to the furnace due to the rupture of the crucible.
-The machine set the highest working temperature is 1150 ℃.
Capacity/Power
-1kg/1500W
-2kg/1600W
-3kg/1700W
Power supply:220V/110V(Optional)
Dimensions:380*380*420mm
Replacement graphite crucible please click here to purchase.
Country of origin: China